ACCESSORIES for PHT-6000 series Hardness Testers:
Item#/Part# | Descriptions |
PHT6000-0100 | Support handle for 100kg manual probe |
PHT6000-221 | 0.3kgf Motorized Probe |
PHT6000-241 | 0.8KGF Motorized Probe |
PHT6000-251 | 1kg Motorized Probe |
PHT6000-301 | Replacement Cable for UCI Probes |
PHT6000-310 | 1kg Manual probe |
PHT6000-320 | 2kg Manual Probe |
PHT6000-330 | LONG 1kg Manual Probe |
PHT6000-350 | 5kg Manual Probe |
PHT6000-400 | 10kg Manual Probe |
PHT6000-511 | Flat Support Ring (manual probes only) |
PHT6000-521 | Small Cylindrical Support Ring (manual probes only) |
PHT6000-531 | Large Cylindrical Support Ring (manual probes only) |
PHT6000-711 | Standard probe protector |
PHT6000-721 | Deep Hole Protector (manual probes only) |
PHT6000-731 | Deep Hole Protector (motorized probes only) |
PHT6000-751 | V-Support Ring (Motorized probes only) |
PHT6000-941 | Replacement Lithium Battery pack |
PHT6000-MAN | Support Stand for Manual Probe units |
PHT6000-MOT | Support Stand for Motorized Probe units |
PHT6000-USB | USB Cable (for charging and data output) |
About PHT-6000 Series Portable Hardness Tester:
Features
Latest portable hardness tester technology. Utilizes both ultrasonic and dynamic type portable hardness testers in one unit. Can test non-destructive and handle small or thin work parts down to 2mm of thickness, as well as testing large parts. Extremely versatile, with many options and configurations to handle all types of hardness tester applications.
w/Manual Probe
w/Motorized Probe
w/LEEB Impact Device
w/Extended Manual Probe
Features:
- Non-Destructive hand held hardness tester
- Combines UCI and Leeb hardness testing in one state of the art device
- Test steel with min thickness of .08” and unlimited max thickness
- Blazing fast test results
- Rockwell, Brinell Vickers conversions shown on display
- Large Memory w/USB Output
- Choice of manual UCI probes; 1kg, 2kg, 5kg & 10kg
- Optional Motorized Probes: .30kg, .80kg, & 1kgf
- Available Impact Devices(Leeb) D, DC, D+15, G & DL
“Ultrasonic Contact Impedance” is based on a 136 degree diamond at the end of a vibrating rod being depressed into the test surface at a fixed load. The difference in Ultrasonic vibration frequency is then calculated into a hardness value. The UCI hardness test procedure is slower than the Dynamic Impact style, however the “UCI” method of hardness testing is portable, easy and accurate. It also has its own advantages when utilized for certain hardness testing applications. UCI hardness testers are not restricted to large mass items like dynamic type testers. These hardness testers can test metals as thin as 2mm and at a hardness value as low as 20HRC (75HB). They also excel at performing hardness tests on larger, harder metals as well. Another reason for the rise in popularity is due to the fact that the UCI method is categorized as “Non-Destructive”. That translates into less scrap parts/ lower mfg costs due to necessary inspections.
“Dynamic Impact” is based on the Leeb principle of hardness developed by Dietmar Leeb in the 1970’s. A spring loaded impact body is thrust to the test surface, effecting rebound. The speed of both the initial thrust and the rebound is measured in a non-contact mode. This is calculated as a Leeb hardness value and then automatically converted to Rockwell C, B, Brinell, Vickers and Shore hardness Values. It has effectually brought easy, fast and accurate results to portable hardness testing.
UCI
Scales-UCI | Measurement Range | Tolerance |
---|---|---|
Rockwell C | 20-70 HRC | +/- 1.5 HRC |
Rockwell B | 41-99 HRB | +/-1.5 HRB |
Rockwell A | 61-85 HRB | +/-1.5 HRA |
Brinell | 76-618 HB | +/- 3% HB |
Vickers | 80-1599 HV | +/- 3% HV |
Can also test in the following scales(UCI only) HRN15 – HRN30 – HRN45 – HRT15 – HRT30 – HRT45 HRF – HK – HD.
LEEB
Scales-Leeb | Measurement Range | Tolerance |
---|---|---|
Rockwell C | 25-67 HRC | +/- 1.5 HRC |
Rockwell B | 59-99 HRB | +/-1.5 HRB |
Brinell | 85-651 HB | +/- 10 HB |
Vickers | 83-976 HV | +/- 12 HV |
Shore | 26-99HS | +/-10HS |
Leeb | 170-960HLD | +/- 6HL |
UCI hardness tester w/manual probe
Model No. | Description | Application Notes |
---|---|---|
PHT-6001 | UCI Portable Hardness Tester w/1kgf Probe | For surfaces with Ra below 125?in |
PHT-6002 | UCI Portable Hardness Tester w/2kgf Probe | For surfaces with Ra below 200?in |
PHT-6005 | UCI Portable Hardness Tester w/5kgf Probe | For surfaces with Ra below 400?in |
PHT-6010 | UCI Portable Hardness Tester w/10kgf Probe | For surfaces with Ra below 600?in |
PHT-6011 | UCI Portable Hardness Tester w/LONG 1kgf Probe | For Deep Groove surfaces with Ra below 125?in |
UCI hardness tester w/motorized probe
Model No. | Description | Application Notes |
---|---|---|
PHT-6030 | UCI Hardness Tester w/.30kgf Probe | Best for checking coating layer hardness; Finished thin parts |
PHT-6080 | UCI Hardness Tester w/.80kgf Probe | Best for smooth bearing type surfaces |
PHT-6100 | UCI Hardness Tester w/1kgf Probe | Best for machined surfaces |
Specifications:
Hardness Range | HRC: 20.3- 70; HRB: 61-85.6 ; HV: 80-1599; HB: 76-618 |
---|---|
Scale Selection | Rockwell C (HRC); Rockwell B (HRB); Rockwell A (HRA); Brinell (HB); Vickers (HV); Leeb (HLD) and many more! |
Tolerance | +/- 3.0% deviation of average from the reference value of the test block with a minimum of 5 tests |
Display type | LCD Color Screen w/Backlight, adjustable brightness |
Language Selection | English, German, Chinese, Spanish, etc. |
Data Logger | Letters, Numerals |
Data Memory | 2000 groups of measured data ; 20 groups of calibration data |
Statistical Software | Supplied-can be saved in Word or Excel |
Data Output | USB – cable supplied |
Power Supply | Rechargeable Lithium Battery: Voltage-4.2V, 4800mAh |
Auto Power Off | 5 minutes |
Recharging Time | Approx. 8 hours |
Battery Usage | Approx. 6 hours (no backlight) |
Net Weight(base unit) | 2lbs (w/probe) |
Gross Weight | 12 lbs |
Unit Dimensions | 7.0 x 3.1 x 1.1” (160x80x30mm) |
Gross Dimensions | 13.7 x 17.7 x 5.9” (350x450x150mm) |
Manual UCI Probe Specifications:
Probe Type/Model | PHT-6001 | PHT-6002 | PHT-6005 | PHT-6010 | PHT-6011 |
---|---|---|---|---|---|
Loading Force | 1kgf (10N) | 2kg (20N) | 5kg (50N) | 10kg (98N) | 1kgf (10N) |
Probe Diameter | 22mm | 22mm | 22mm | 22mm | 22mm |
Length | 154mm | 154mm | 154mm | 154mm | 213mm |
Oscillating Rod Diameter | 2.4mm | 2.4mm | 3mm | 3mm | 2.4mm |
Surface Roughness Requirements ?m=Metric ?in= Inch |
Ra<3.2?m (Ra<125 ?in) |
Ra<5?m (Ra<197 ?in) |
Ra<10 ?m (Ra<393 ?in) |
Ra<15 ?m (Ra<590 ?in) |
Ra<3.2µm (Ra<125 µin) |
Min weight of test sample | 0.3kg (.66lbs) | 0.3kg (.66lbs) | 0.3kg (.66lbs) | 0.3kg (.66lbs) | 0.3kg (.66lbs) |
Minimum thickness of sample | 2mm (.08”) | 2mm (.08”) | 2mm (.08”) | 2mm (.08”) | 2mm (.08”) |
Motorized UCI Probe Specifications:
Probe Type/Model | PHT-6030 | PHT-6080 | PHT-6100 |
---|---|---|---|
Loading Force | .30kg (3N) | .80kg (8N) | 1kgf (10N) |
Probe Diameter | 46mm | 46mm | 46mm |
Length | 198mm | 198mm | 198mm |
Oscillating Rod Diameter | 3.7mm | 3.7mm | 3.7mm |
Surface Roughness | Ra<3.2?m | Ra<5 ?m | Ra<8 ?m |
Requirements ?m=Metric ?in= Inch |
(Ra<125 ?in) | (Ra<197 ?in) | (Ra<314 ?in) |
Min weight of test sample | 0.3kg (.66lbs) | 0.3kg (.66lbs) | 0.3kg (.66lbs) |
Minimum thickness of sample | 2mm (.08”) | 2mm (.08”) | 2mm (.08”) |
Indentation Depth (?m)
Hardness | .30kg Motorized | .80kg Motorized | 1kg Motorized | 1kg Manual | 2kg Manual | 5kg Manual | 10kg Manual |
---|---|---|---|---|---|---|---|
800HV | 4 | 5 | 7 | 7 | 10 | 15 | 22 |
600HV | 4 | 5 | 8 | 8 | 11 | 18 | 25 |
500HV | 5 | 6 | 9 | 9 | 12 | 19 | 27 |
300HV | 6 | 8 | 11 | 11 | 16 | 25 | 35 |
100HV | 10 | 13 | 19 | 19 | 27 | 43 | 61 |
OPTIONAL ACCESSORIES:
Special Application Impact Devices
-
Impact Device D : Part No. PHT1800-100
Universal standard device:
Use for the majority of hardness testing assignments -
Impact Device DL : Part No. PHT1800-115
Tip 4mm diameter x 1.96” length Measurements in extremely confined spaces -
Impact Device G : Part No. PHT1800-125
Enlarged test tip:
For use on solid heavy components such as; rough castings and forgings. Brinell only. -
Impact Device DC : Part No. PHT1800-120
Extremely short impact device
Used for very confined spaces such as holes, cylinders, internal measurements -
Impact Device D+15 : Part No. PHT1800-110
Slim front section with coil set back
Hardness measurements in grooves, recessed surface -
Impact Device C : Part No. PHT1800-130
Reduced impact energy
For testing case hardened material